Page 1 Cover Page
Page 2 Certificate Page
Page 4 Section 00010 Table of Contents
Page 10 Section 00030 Solicitation for Bids
Page 12 Section 00100 Instructions to Bidders
Page 30 Section 00200 Information Available to Bidders
Page 34 Section 00300 Bid Form
Page 40 Section 00310 Information Required of Bidder
Page 42 Section 00320 Bid Security
Page 44 Section 00330 Mandatory Bidder Responsibility Checklist
Page 46 Section 00340 Bidder's Qualification Form
Page 48 Section 00360 Subcontractors List
Page 50 Section 00370 Mandatory Subcontractor Responsibility Checklist
Page 52 Section 00380 Non-Collusion Affidavit
Page 54 Section 00500 Agreement
Page 58 Section 00610 Performance, Payment & Guaranty Bond
Page 60 Section 00620 Declaration of Option for Management of Statutory Retained Percentage
Page 62 Section 00660 Insurance Requirements
Page 66 Section 00665 Insurance Questionnaire & Certificate
Page 68 Section 00720 General Conditions
Page 110 Section 00820 Prevailing Wages
Page 112 Section 01010 Summary of Work
Page 116 Section 01014 Construction Constraints & Sequence
Page 124 Section 01025 Measurement & Payment
Page 132 Section 01135 Special Safety & Health Requirements
Page 136 Section 01300 Project Data Submittals
Page 144 Section 01320 Project Scheduling
Page 150 Section 01350 Administrative Requirements
Page 158 Section 01400 Quality Assurance, Inspection & Testing
Page 164 Section 01500 Temporary Construction Facilities
Page 170 Section 01640 Installation of Owner-Furnished Equipment
Page 174 Section 01660 Facility Start-Up & Testing
Page 188 Section 01665 Facility Training
Page 190 Section 01730 Operation & Maintenance Data
Page 194 Section 01780 Closeout Procedures
Page 200 Section 02010 Subsurface Investigations
Page 202 Section 02050 Demolition
Page 210 Section 02110 Site Clearing
Page 212 Section 02150 Temporary Shoring
Page 214 Section 02210 Earthwork
Page 222 Section 02222 Excavating, Backfilling & Compacting for Utilities
Page 232 Section 02230 Tree Preservation
Page 238 Section 02275 Temporary Erosion & Sedimentation Control
Page 244 Section 02513 Hot Mix Asphalt (HMA) Paving
Page 250 Section 02530 Buried Utilities
Page 256 Section 02630 Storm Drainage
Page 262 Section 02750 Site Concrete
Page 264 Section 03002 Concrete, Reinforcing Steel & Grouts
Page 286 Section 05400 Cold Formed Metal Framing
Page 296 Section 05500 Metal Fabrications
Page 302 Section 07210 Building Insulation
Page 308 Section 07600 Flashing & Sheet Metal
Page 316 Section 07920 Caulking & Sealants
Page 322 Section 08110 Hollow Metal Doors & Frames
Page 328 Section 08700 Finish Hardware
Page 338 Section 09210 Gypsum Board
Page 348 Section 09220 Light-Gauge Metal Framing
Page 356 Section 09900 Painting
Page 364 Section 11010 Equipment General Provisions
Page 376 Section 11500 Digester Gas Handling Equipment
Page 380 Section 11630 Hot Water Boiler Package Installation
Page 384 Section 13053 Seismic Restraint Requirements for Non-Structural Components
Page 390 Section 15000 Common Work Results for HVAC & Plumbing
Page 398 Section 15010 General Mechanical Provisions
Page 412 Section 15030 Mechanical Painting & Identification
Page 414 Section 15040 Balancing Air & Water Systems
Page 420 Section 15065 Stainless Steel Pipe & Fittings
Page 426 Section 15070 Mechanical System Insulation
Page 434 Section 15080 Piping Appurtenances
Page 438 Section 15090 Piping & Mechanical Equipment Support
Page 448 Section 15110 Gas Service Plug Valves
Page 452 Section 15180 HVAC Water Treatment
Page 454 Section 15181 Hydronic Pumps & Piping
Page 468 Section 15517 Sleeves & Sleeve Seals for HVAC
Page 472 Section 15700 Basic Mechanical Materials & Methods
Page 482 Section 15710 Hangers & Supports
Page 486 Section 15720 Mechanical Sound, Vibration & Seismic Control
Page 492 Section 15725 Mechanical Identification
Page 496 Section 15730 Small-Capacity Split-System Air Conditioners
Page 500 Section 15760 Convection Heating & Cooling Units
Page 502 Section 15810 HVAC Ducts & Casings
Page 508 Section 15820 Air Duct Accessories
Page 510 Section 15830 Centrifugal HVAC Fans
Page 516 Section 15850 Air Outlets & Inlets
Page 520 Section 15950 Commissioning of HVAC
Page 528 Section 16010 Electrical Work - General
Page 542 Section 16020 Identification for Electrical Systems
Page 550 Section 16090 Seismic Controls for Electrical Systems
Page 556 Section 16110 Raceways & Boxes for Electrical Systems
Page 564 Section 16120 Conductors & Cables
Page 574 Section 16140 Wiring Devices
Page 580 Section 16160 Motor Starters
Page 586 Section 16164 Panelboards
Page 596 Section 16190 Hangers & Supports for Electrical Systems
Page 600 Section 16230 Transfer Switches Installation
Page 604 Section 16410 Enclosed Switches & Circuit Breakers
Page 610 Section 16426 Switchboard Installation
Page 614 Section 16450 Grounding & Bonding for Electrical Systems
Page 620 Section 16460 Low-Voltage Transformers
Page 626 Section 16481 Motor-Control Center Installation
Page 632 Section 16500 Lighting
Page 638 Section 16621 Engine Generator Installation
Page 642 Section 16941 Electrical Demonstration
Page 652 Section 16995 Electrical Systems Independent Testing
Page 656 Section 17050 Common Requirements for Process Instrumentation
Page 662 Section 17051 Control System Installation
Page 666 Section 17113 Magnetic Flow Meters
Page 670 Section 17138 Positive Displacement Meters
Page 676 Section 17176 Thermal Flow Meters
Page 678 Section 17243 Pressure & Differential Pressure Type Level Meters
Page 680 Section 17313 Pressure Gauges
Page 682 Section 17363 Diaphragm Seals
Page 684 Section 17413 Resistance Temperature Devices
Page 688 Section 17463 Temperature Transmitters